Free tool
DMX Address Calculator
Turn an Art-Net port-address into Net, Sub-Net and Universe and back, find the multicast address for an sACN universe, set a start address on DIP switches, and work out the next free address after a run of fixtures.
Runs entirely in your browser. The URL updates as you work, so a setting can be sent to whoever is up the ladder as a link.
Art-Net port-address
Art-Net numbers a universe with one 15-bit port-address, which a node splits into Net, Sub-Net and Universe. Change either side and the other follows.
- Net / Sub-Net / Universe
- 0/0/0
- Port-address in hex
- 0x0000
- Sub-Net and Universe as one byte
- 0
- For a node with a single 0-255 universe setting.
- On a console that counts from 1
- Universe 1
Art-Net counts from 0. Port-address 0 is the 1st universe, so a console or node that numbers universes from 1 shows it as universe 1, and the sACN universe usually paired with it is 1. If every fixture answers one universe out, this is the first thing to check.
Art-Net travels on UDP port 6454. Art-Net 1 and 2 nodes have no Net field and reach port-addresses 0 to 255 only.
sACN universe to multicast address
Each sACN universe is sent to its own multicast group. The address is fixed by the universe number, and works back from one too.
- Universe 1 is sent to
- 239.255.0.1
- High byte . low byte
- 0 . 1
- 1 = 0 × 256 + 1
- Matching Art-Net port-address
- 0 (0/0/0)
- One lower, because Art-Net counts from 0.
sACN travels on UDP port 5568. Unicast sACN goes to the receiver's own IP address instead and does not use the multicast group. Data universes run from 1 to 63,999.
DMX start address to DIP switches
Each switch is worth double the one before it, starting at 1. The address is the sum of the switches that are on. Type an address, or flip the switches.
Address 1: Switch 1 on, the rest off.
1 = 1
Check the chart printed on the fixture before trusting any calculator. On many ten-switch fixtures switch 10 selects a mode rather than adding 512, and a few older dimmers count from 0, so the switches read one less than the address.
Next free address
Patch a run of identical fixtures back to back from address 1 and see where each one starts, and where the next fixture can go.
- Next free address
- 129
- Fixtures that fit
- 8 of 8
- Channels used
- 128
- Channels left to 512
- 384
| Fixture | Start | End | Fits |
|---|---|---|---|
| 1 | 1 | 16 | Yes |
| 2 | 17 | 32 | Yes |
| 3 | 33 | 48 | Yes |
| 4 | 49 | 64 | Yes |
| 5 | 65 | 80 | Yes |
| 6 | 81 | 96 | Yes |
| 7 | 97 | 112 | Yes |
| 8 | 113 | 128 | Yes |
These are the numbers an Art-Net or sACN output asks for. CueSync sends DMX over both, with sACN as multicast or unicast. With a free account you can run the demo show and tour the app in read-only mode.
Download CueSync with a free accountBinary DIP-switch weights (switches 1 to 9)
Add the values of every switch in the ON position to get the DMX512 start address. Switch 10 is either channel 512 or a fixture mode toggle depending on the hardware.
| Switch | Power of two | Address value | Reachable range |
|---|---|---|---|
| DIP 1 | 2^0 | +1 | 1–1 |
| DIP 2 | 2^1 | +2 | 1–3 |
| DIP 3 | 2^2 | +4 | 1–7 |
| DIP 4 | 2^3 | +8 | 1–15 |
| DIP 5 | 2^4 | +16 | 1–31 |
| DIP 6 | 2^5 | +32 | 1–63 |
| DIP 7 | 2^6 | +64 | 1–127 |
| DIP 8 | 2^7 | +128 | 1–255 |
| DIP 9 | 2^8 | +256 | 1–511 |
Art-Net 4 & ANSI E1.31 sACN universe landmarks
The same physical 512-channel universe expressed as a 0-based Art-Net port-address (Net/Sub-Net/Universe) and a 1-based sACN multicast group.
| Console universe | Art-Net port (N/S/U) | Art-Net UDP | sACN multicast | sACN UDP |
|---|---|---|---|---|
| Universe 1 | 0 (0/0/0) | UDP 6454 | sACN 1 (239.255.0.1) | UDP 5568 |
| Universe 16 | 15 (0/0/15) | UDP 6454 | sACN 16 (239.255.0.16) | UDP 5568 |
| Universe 17 | 16 (0/1/0) | UDP 6454 | sACN 17 (239.255.0.17) | UDP 5568 |
| Universe 256 | 255 (0/15/15) | UDP 6454 | sACN 256 (239.255.1.0) | UDP 5568 |
| Universe 301 | 300 (1/2/12) | UDP 6454 | sACN 301 (239.255.1.45) | UDP 5568 |
Addressing questions, answered
- How do I work out Art-Net Net, Sub-Net and Universe from a universe number?
- Divide the port-address by 256: the whole part is the Net. Divide what is left by 16: the whole part is the Sub-Net and the remainder is the Universe. Port-address 300 is 1 × 256 + 2 × 16 + 12, so Net 1, Sub-Net 2, Universe 12. Going back, multiply the Net by 256, the Sub-Net by 16, and add all three.
- Why is my Art-Net universe off by one?
- Because Art-Net counts universes from 0 and most consoles, and sACN, count from 1. The first Art-Net universe is port-address 0 (Net 0, Sub-Net 0, Universe 0), which a console that counts from 1 calls universe 1. If every fixture responds one universe away from where it was patched, one end of the link is counting from 0 and the other from 1.
- What is the sACN multicast address for a universe?
- 239.255. followed by the universe number as two bytes: the universe divided by 256, then the remainder. Universe 1 is 239.255.0.1, universe 256 is 239.255.1.0 and the last, 63999, is 239.255.249.255. Every universe uses UDP port 5568. Unicast sACN is sent to the receiver's own IP address and does not use these groups.
- How do I set a DMX address with DIP switches?
- Turn on the switches whose values add up to the address. Switch 1 is worth 1 and each switch after it doubles: 2, 4, 8, 16, 32, 64, 128, 256. Address 205 is 128 + 64 + 8 + 4 + 1, so switches 1, 3, 4, 7 and 8 are on. Nine switches reach 511; on a ten-switch fixture, check whether switch 10 is 512 or a mode switch.
- What is the next DMX address after a fixture?
- The fixture's start address plus the number of channels it uses. A 16-channel fixture at address 1 occupies 1 to 16, so the next starts at 17, and eight of them end at 128 with 129 free. A fixture cannot run past channel 512: one that would has to start at address 1 of the next universe.
Going deeper on DMX over IP
Art-Net™ Designed by and Copyright Artistic Licence Engineering Ltd. CueSync is an independent product and is not affiliated with or endorsed by Artistic Licence.