Guides5 min read
LTC, MTC or Art-Net Timecode: Which Should Run the Show?
LTC rides an audio cable, MTC a MIDI port, Art-Net timecode the lighting network. What each one carries, where each fails, and how to choose for a rig.
CueSync TeamShow Control Engineers
Same Position, Three Wires
LTC, MTC and Art-Net timecode are three ways of moving one thing: a SMPTE position, written HH:MM:SS:FF. A console chasing any of them fires the same cue at the same frame. What changes is the cable, what the receiver needs, and how each one behaves when something goes wrong.
| LTC | MTC | Art-Net timecode | |
|---|---|---|---|
| Carried as | An audio signal | MIDI messages | UDP packets, port 6454 |
| Travels on | An audio line or a multicore channel | A MIDI cable, USB or network MIDI | The lighting network |
| The receiver needs | An audio input | A MIDI input | A port on the Art-Net network |
| Says its frame rate | Drop-frame flag only | Four rate codes | Four rate codes |
| Above 30 fps | Keep to 30 or below | No: frames above 31 wrap | No code for it |
LTC: Timecode as Audio
LTC encodes every frame as an audio signal. That makes it the most portable of the three: it can sit on a playback track beside the show audio, travel down a spare multicore channel to the lighting position, and be split to several receivers with an ordinary audio splitter. When the sound department owns the clock, LTC is usually how it reaches everyone else.
Its weak spots are the ones every audio line has. Too hot and it clips, too quiet and the receiver cannot lock. CueSync's LTC input shows a level bar that stays green across the range a desk's LTC normally sits in, turns amber when the feed runs hot, red when it clips, and amber with a "Level is low" line when the signal is too weak to lock. CueSync opens only the audio input you chose for LTC, and if that interface drops mid-show, from a nudged cable or a USB brown-out, it re-opens it as soon as the device is back.
MTC: Timecode as MIDI
MTC sends the position as MIDI. While the clock runs it streams quarter-frame messages, and it takes eight of them, spread across two frames, to describe one complete position. A receiver that does nothing about this reads every position two frames late. The SMPTE specification asks the receiver to add the two frames back, and CueSync does by default, so an MTC-triggered cue lands on its frame rather than 80 ms behind it at 25 fps.
MTC suits rigs whose desks already have MIDI inputs, and it fans out well. In CueSync, Additional MTC Devices sends the same MTC stream to several consoles on separate MIDI ports, so front of house, lighting and a safety desk each get their own interface. On the receiving side, pin the show clock to one interface (Settings → Timecode → MTC Input Device) when several are patched, so a spare console or a laptop left running cannot take the clock mid-show.
MTC cannot carry the high frame rates. Its frame count stops at 31, so a 50 or 60 fps clock arrives with the wrong frames.
Art-Net Timecode: Timecode on the Lighting Network
On a rig where the consoles and media servers already share an Art-Net network, Art-Net timecode needs no extra cable at all. It also carries a stream number, so one sender can feed several clocks: in DJ and Production, CueSync can send each CDJ's own playhead as its own Art-Net stream, and a grandMA3 follows the stream its input is set to.
Two traits matter in a show. The rate field has codes for 24, 25, 29.97 drop-frame and 30 only, so a 23.976 or a 29.97 non-drop master has to be declared on the receiver. And there is no stop flag: a paused master just goes quiet. CueSync's Silence means stopped setting, on by default for Art-Net, reads that quiet as a pause and holds the clock, so no cue fires past a point the console never reached. Switch it off for a source that can really drop out, and the clock freewheels instead.
CueSync follows one Art-Net timecode sender at a time. The first sender heard is followed, a second one is ignored and named in a warning, and Art-Net stream to follow pins the clock to one stream. It also never chases its own Art-Net timecode, so a dead master still fails over correctly while CueSync is sending.
How to Choose
- The consoles are networked and nothing else needs the clock: Art-Net timecode. No cable, and stream numbers if several desks need different clocks.
- The sound department runs the show from a playback track: LTC, recorded on the track and split to every department.
- Several desks with MIDI inputs, or a desk with no network timecode input: MTC, fanned out to each.
- Video runs at 50 or 60 fps: keep the timecode itself at 30 fps or below on all three wires.
You rarely have to pick only one. CueSync generates LTC, MTC, Art-Net timecode and TCNet at the same time in every edition, from its own clock or from your CDJs, and the routing matrix on the Timecode screen sends each output the clock it needs.
Rules for Any of the Three
One master. Everything else chases it. Two generators on one show is the most common way a rehearsed show fails live.
One frame rate, declared on every receiver. Check it on each console; do not assume it was inherited. The frame rate guide covers drop-frame and what a mismatch costs.
A rehearsed failure. Pull the cable in rehearsal and watch what each receiver does. In CueSync a dropped source freewheels on its last good frame for 5 seconds by default, and a live lower-priority source takes the clock after the source timeout, 2 seconds by default; chasing an incoming clock, with its source priority list and Force, is part of Theatre and Production.
Further Reading
- LTC Generator and Timecode Calculator
- How to Send Timecode to grandMA3 and Where Should Your Show's Timecode Come From?
- Timecode in the manual, and Timecode with CueSync
grandMA3® is a registered trademark of MA Lighting International GmbH. Art-Net™ is a trademark of Artistic Licence Holdings Ltd. CueSync is independent software and is not affiliated with or endorsed by either company.
Frequently Asked Questions
What is the difference between LTC and MTC?
LTC (linear timecode) encodes each frame as an audio signal that can be patched, recorded and split like any audio line. MTC (MIDI timecode) sends the same position as MIDI messages: quarter-frame messages while the clock runs, eight of which make up one position across two frames, and a full-frame message when the clock is located. A receiver needs an audio input for LTC and a MIDI input for MTC.
Is MTC less accurate than LTC?
Not when the receiver corrects it. A complete MTC position is two frames old by the time it is assembled, and the SMPTE specification asks the receiver to add those two frames back. CueSync does this by default (Settings → Timecode → MTC Input Compensation); without it every MTC-triggered cue would fire two frames late, 80 ms at 25 fps.
Can MTC carry 50 or 60 fps timecode?
No. MTC cannot count frames above 31, so frame 35 is sent as frame 3 and the receiver reads the wrong frame. Keep MTC and LTC at 30 fps or below. CueSync warns when a high frame rate is chosen with an MTC, LTC or Art-Net timecode output on.
Why does my 29.97 non-drop timecode read as 30?
Art-Net timecode's rate field has codes for 24, 25, 29.97 drop-frame and 30 only, and LTC carries a drop-frame flag but no rate. A 29.97 non-drop master therefore looks like 30, and the clock runs 0.1 % short, about 1.8 seconds per half hour. Declare the rate on the receiver: in CueSync, MTC Rate Code 3 is 29.97 non-drop covers MTC, Art-Net timecode and LTC input.
What happens when the timecode master pauses?
LTC and Art-Net timecode have no stop flag, so a paused master goes silent, which a receiver cannot tell from a pulled cable. CueSync lets you choose per source: Silence means stopped clears the clock at once (on by default for Art-Net, because a paused grandMA3 timecode slot sends nothing), and with it off the clock freewheels for the freewheel window, 5 seconds by default.
Do this with CueSync
CueSync fires your show's cues — lights, video, playback — from the music, a timecode or your GO, on the gear you already use.
- MIDI, MIDI clock, OSC and Ableton Link with CueSync
- Timecode with CueSync: LTC, MTC, Art-Net and TCNet
Keep Reading
- Guides
23.976, 29.97 Drop-Frame, 25, 30 fps: Stop Timecode Drift
How 23.976, 29.97 drop-frame, 29.97 non-drop, 25 and 30 fps behave across LTC, MTC and Art-Net timecode, and how to stop drift on a live show.
- Guides
How to Send Timecode to grandMA3: LTC, MTC and Art-Net
grandMA3 can follow SMPTE/LTC, MIDI timecode or Art-Net timecode. How each reaches the console, which to choose, and what happens when the source drops.
- Guides
Where Should Your Show's Timecode Come From?
Reaper, QLab, the console's internal clock, or the live performance itself: four architectures, how to choose, and where a hardware generator fits.